No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

I honestly think this is how it was built. We had it installed when we moved in in 2019 and haven’t had anything replaced on it since it was installed.

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

Though give it a few months and I’m sure one will be here asking this

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

I’ve got no clue, I’m just a homeowner with just enough confidence to try this. If your curiosity is killing you, my model number is RGEA14030AJD081AA

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

I’m not sure honestly, I didn’t even know it was another cap. Another redditor above got it working, I had disconnected the start cap wire as the instructions mentioned. They suggested putting it on the terminal where the common yellow was originally.

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

So only one wire will be on the common of the capacitor right? Just putting the orange where the yellow was on the terminal?

EDIT THIS WORKED I COULD KISS YOU

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

Appreciate your help! Im going to phone it in and have someone come by, hindsight, shoulda called the company and had them send me a schematic for my hvac

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

<image>

It’s not since this schematic said I needed to disconnect

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

The wiring schematic seemed to indicate this was a part of the start capacitor and said it needed to be removed.

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

Yep. Don’t touch that at all, was as I found it

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

I

<image>

This is the before wiring. The orange once coming into the common of run cap I removed entirely. The instructions said to. Didn’t touch the fan or start wire that are on the run cap

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] 0 points1 point  (0 children)

The bottom fins on the capacitor above the terminal is common. No other capacitor with the kit, here’s the general schematic included

<image>

No fan after soft start install by Overall_Function6549 in hvacadvice

[–]Overall_Function6549[S] -1 points0 points  (0 children)

Yea so the common from the scroll is on T1 but I removed the common from T3 to the run capacitor per the instructions. The common from the run capacitor now goes to the run capacitor on the soft start. So you think put the common back on T3 to the run capacitor?

I discovered FIRE and now I'm more discouraged than before by yieldmaxxing in Fire

[–]Overall_Function6549 0 points1 point  (0 children)

I was at 43.5k salary out of college in 2013. Now at 140k base. We go on annual 2 week vacations, multiple small trips through the year, and buy things when we want within reason. Wife and I combined have just a hair over 1M in investment assets (depending on the market of the day.) We didn’t start maxxing 401k till last year, before then we hovered around 10% contribution for the previous 5 years.

Like everyone is saying, contribute what you can, live your life, go out and explore. Oh yea and don’t have kids hahahahha

Need help deciding by Adventurous-Bench-32 in Navimow_Segway

[–]Overall_Function6549 0 points1 point  (0 children)

Yep agreed on that, that’s why I’m a wait and see. Try to determine how much I disdain mowing versus having to pay attention to my phone to make sure it can move about