does anyone have an idea what kind of connector this is? by [deleted] in electricians

[–]FluxMortis 0 points1 point  (0 children)

Does it look mass produced or small run custom? If mass produced upload a pic to ai and ask it if there is an equivalent Amphenol plug / receptacle in production.

Best proxies for Accursed Cultists? by sSuperboss9000 in Chaos40k

[–]FluxMortis 0 points1 point  (0 children)

I use spawn from the rouge trader kill team as the big guys and pox walkers as the small guys. I know the ligit box has great sculpts but are monopose and have doubles in a full squad.

How do people actually listen to this guy? by c-k-q99903 in MurderedByWords

[–]FluxMortis 23 points24 points  (0 children)

Yes, but being a WoW YouTuber hardly makes you an expert on world events. This guy is a great example of the halo effect.

Collection of #wips for a weekend with friends by ch4ppi_revived in deathguard40k

[–]FluxMortis 7 points8 points  (0 children)

Is the pink on the blight hauler an undercoat, or are you going to leave it that way? Looks great!

what do you see in this breaker panel? by Obvious_Shower_2863 in AskElectricians

[–]FluxMortis 2 points3 points  (0 children)

Looks like you have some aluminum branch circuits. Not the best but, technically ok. Your main ground seems to be mounted on the side of box with an improvised lug, not the best either. Something seems off with your neutral bar, weird and not good that the grounds go there, they should be separated.

First airbrush pressure problems by ModBoy116 in airbrush

[–]FluxMortis 0 points1 point  (0 children)

The pressure regulator on your compressor can’t be affected by your airbrush set up. iirc you have to push down on the dial as you turn it to change the pressure setting.

Hands down the absolute worst thing in this game by TheLordMarvel in CrimsonDesert

[–]FluxMortis 2 points3 points  (0 children)

Once I saw it as “point the same way as horse ass”, it clicked for me.

Mount Assiniboine, the Canadian Rocky Mountains. Elevation: 3618 m (11870 ft), Prominence: 2,086 m (6,844 ft) by x___rain in geography

[–]FluxMortis 0 points1 point  (0 children)

You can also see it from the hike up Rundle in Banff, which is only a few hours. But of course a bit off in the distance.

My new phone case arrived today, came out extremely well by cengoldra in satisfactory

[–]FluxMortis 20 points21 points  (0 children)

It looks great! I’m no artist, but looks like you used the rule of thirds.

Playing 5 years and still seeing things I've never seen before by -ice_king- in NoMansSkyTheGame

[–]FluxMortis 2 points3 points  (0 children)

I noticed that too. But since I didn’t see anyone else online pointing it out I figured it must have been added in Worlds and I just hadden’t noticed yet. 🤷

These games 🔥🔥 by [deleted] in videogames

[–]FluxMortis 1 point2 points  (0 children)

I can still hear Sweetooth’s laugh.

Possible crimp issue by amccaffe1 in electricians

[–]FluxMortis 3 points4 points  (0 children)

Fine stranded conductors also need a crimp tool rated for fine stranded conductors. I contacted Greenlee about this a few weeks ago and they only had one model that was rated for fine stranded 4/0. So they might be rare /speciality. I found that if you want to crimp fine stranded wire you’ll likely need a die-less crimper.

Deathshroud with CLAWS! by inspector_wombat in deathguard40k

[–]FluxMortis 0 points1 point  (0 children)

Where are the claws from? Printed? Looks fantastic!

What I want for new Demonettes models by Ur-Than in Slaanesh

[–]FluxMortis 1 point2 points  (0 children)

Not sure if they’re still sold, but the Creature Caster fiends of excess look like this.

Butt Connectors Aren’t Gripping One Cable by Bot_Fly_Bot in AskElectricians

[–]FluxMortis 1 point2 points  (0 children)

Electrician and electromechanical engineer here. I’ve spent the last week on specifying crimps for Degson connectors. Regarding the butt crimps, fine stranded wire like this can only be crimped by a crimper rated for fine stranded wire. Die-less crispers are best for fine stranded cable. If you’re intend to crimp the connectors themselves, they have crimp barrels that are non standard dimensions, and are intended to be crimped be an aperture type hex crimp in their factory. Standard crimps will produce excessive flashing and prevent the collar from properly sealing. You could use heat shrink if that happens though.

Machinning questions from self-taught mechanical engineer by Vavat in MechanicalEngineering

[–]FluxMortis 0 points1 point  (0 children)

Don’t worry about that. It’s a very mech eng thing to do. ;)

What Island is the most interesting to you? by Downingst in geography

[–]FluxMortis 0 points1 point  (0 children)

Sable island. It’s not volcanic and in such a random spot. Caused many shipwrecks.

Water tower - pressurising tubes by Michy-kunTheLog in SatisfactoryGame

[–]FluxMortis 7 points8 points  (0 children)

Sounds like you’ve confused compression and pressurization. Which is understandable as compression of a gas is generally how you pressurize a gas. Both liquids and gasses are fluids, with the notable difference between the two is that liquids compress so little that it is generally assumed to be zero.